Model NO.: CS-810
Trademark: ZSIMC
Transport Package: Export Packing
Specification: 475*340*150mm
Origin: China
HS Code: 9027300000
Model NO.: CS-810
Trademark: ZSIMC
Transport Package: Export Packing
Specification: 475*340*150mm
Origin: China
HS Code: 9027300000
Tabletop Spectrophotometer CS-810
for Liquid/ Glass
                           for Liquid/ Glass
 Â
CS-810 Transmitted liquid Spectrophotometer is good performance and specially designed for testing the liquid transmittance, absorbance, concentration, chrominance and other parameters. The instrument adopts the measurement structure of D/0, integration of the full band LED composite light source, double beam optical system, ETC every-time calibration technology, which makes the instrument reaches a resolution of 0.0001, deviation of the transmittance within 0.08% and chromatic value : â–³E*ab 0.015.
Â
Brief Introduction
1. D\0 Structure
Â
Â
2. It is suitable for testing the glass and liquid color
Â
3. Adopt UV enhanced silicon photodiode
Expend the transmittance from 0~100% to 0~200%
 4. Pt-Co and Gardner Index- Liquid Yellow Degree Characteristics
The unit of Pt-Co is Hazen to show the result. Every liter liquid contains 1mg Platinum with chloroplatinic acid and 2mg cobalt chloride hexahydrate is called one Hazen. Normally, the data is between 1-500. It is suitable for testing transparent liquid or brown liquid whose color similar to one unit Pt-Co calm chroma.
Gardner Color Code: Mix the cobalt chloride solution, ferric trichloride solution, potassium chloroplatinate solution in different proportion, we will get the standard color Chroma. Normally, the data is between 1-18. It is suitable for the liquid whose color is darker than Pt-Co color.
American Public Health Association (APHA): use K2PtCl6 mix with hydrochloric acid to make the standard color chroma and normally the data is between 1-500 which is same as Hazen.
5. Matching color analysis software
Our spectrophotometer comes with the color management software, which is applicable in various industries' quality control and management of color data. It turns color into numerical data, compares color differences, generates measurement reports. provides measurement data under different color spaces and customizes color management for each customer.
Â
6. Technical Data
Type | CS-810 |
Illumination | d/0(Diffused lighting, 0 degrees observe angle) SCS optical engine(light splitting and integration system),(Â conform to CIE No.15, ISO 7724/1, ASTM E1164, DIN 5033 Teil7, JIS Z8722 Condition c standards) |
Size of integrating sphere | Φ40mm,Alvan diffused reflection surface coating |
Illumination Light source | CLEDs(entire wavelength balanced LED light source) |
Sensor | dual light path sensor array |
Wavelength range | 400-700nm |
Wavelength interval | 10nm |
Half spectral width | 5nm |
Reflectivity range | 0-200% |
Reflectivity resolution | 0.01% |
Observation angle | 2°/10° |
Measurement light source |
A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12 CWF,U30,DLF,NBF,TL83,TL84 |
Data being displayed | SPD distribution/data,sample's color values,color difference values/graph,pass/fail results,color error tendency,color simulation,display measurement area,history data color simulation,manual input standard sample,generate measurement report |
Measurement time interval | 2 seconds |
Measurement time | 0.5 seconds |
Color space | CIE-L*a*b,L*C*h,CIE-L*u*v, XYZ, Yxy, Transmittance, Hunterlab, Munsell MI, CMYK |
Color difference formulas |
ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00 ΔEab(Hunter),555color classification |
Other colorimetric indices |
WI(ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby), YI(ASTM D1925,ASTM E313-00,ASTM E313-73), Tint(ASTM E313-00,CIE,Ganz),Metamerism index Milm, Stick color fastness, Color fastness, APHA, Pt-Co, Gardner |
Repeatability | light splitting reflectivity: standard deviation within 0.08% |
color values:ΔE*ab<=0.015(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals,Maximum:0.03) | |
Interface | USB |
Data storage | mass storage |
Light source longevity | 5 years, 1.5 million tests |
Size | 475*340*150mm(L*W*H) |
Weight | about 7kg |
Work temperature range | 0~45ºC, relative humidity 80% or below (at 35°C), no condensation |
Storage temperature range | 25ºC to 55ºC, relative humidity 80% or below (at 35°C), no condensation |
Standard accessories | AC power line, color management software, drive software, USB cable, black calibration tube, 40*10mm cuvette |
Tabletop Spectrophotometer CS-810
for Liquid/ Glass
                           for Liquid/ Glass
 Â
CS-810 Transmitted liquid Spectrophotometer is good performance and specially designed for testing the liquid transmittance, absorbance, concentration, chrominance and other parameters. The instrument adopts the measurement structure of D/0, integration of the full band LED composite light source, double beam optical system, ETC every-time calibration technology, which makes the instrument reaches a resolution of 0.0001, deviation of the transmittance within 0.08% and chromatic value : â–³E*ab 0.015.
Â
Brief Introduction
1. D\0 Structure
Â
Â
2. It is suitable for testing the glass and liquid color
Â
3. Adopt UV enhanced silicon photodiode
Expend the transmittance from 0~100% to 0~200%
 4. Pt-Co and Gardner Index- Liquid Yellow Degree Characteristics
The unit of Pt-Co is Hazen to show the result. Every liter liquid contains 1mg Platinum with chloroplatinic acid and 2mg cobalt chloride hexahydrate is called one Hazen. Normally, the data is between 1-500. It is suitable for testing transparent liquid or brown liquid whose color similar to one unit Pt-Co calm chroma.
Gardner Color Code: Mix the cobalt chloride solution, ferric trichloride solution, potassium chloroplatinate solution in different proportion, we will get the standard color Chroma. Normally, the data is between 1-18. It is suitable for the liquid whose color is darker than Pt-Co color.
American Public Health Association (APHA): use K2PtCl6 mix with hydrochloric acid to make the standard color chroma and normally the data is between 1-500 which is same as Hazen.
5. Matching color analysis software
Our spectrophotometer comes with the color management software, which is applicable in various industries' quality control and management of color data. It turns color into numerical data, compares color differences, generates measurement reports. provides measurement data under different color spaces and customizes color management for each customer.
Â
6. Technical Data
Type | CS-810 |
Illumination | d/0(Diffused lighting, 0 degrees observe angle) SCS optical engine(light splitting and integration system),(Â conform to CIE No.15, ISO 7724/1, ASTM E1164, DIN 5033 Teil7, JIS Z8722 Condition c standards) |
Size of integrating sphere | Φ40mm,Alvan diffused reflection surface coating |
Illumination Light source | CLEDs(entire wavelength balanced LED light source) |
Sensor | dual light path sensor array |
Wavelength range | 400-700nm |
Wavelength interval | 10nm |
Half spectral width | 5nm |
Reflectivity range | 0-200% |
Reflectivity resolution | 0.01% |
Observation angle | 2°/10° |
Measurement light source |
A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12 CWF,U30,DLF,NBF,TL83,TL84 |
Data being displayed | SPD distribution/data,sample's color values,color difference values/graph,pass/fail results,color error tendency,color simulation,display measurement area,history data color simulation,manual input standard sample,generate measurement report |
Measurement time interval | 2 seconds |
Measurement time | 0.5 seconds |
Color space | CIE-L*a*b,L*C*h,CIE-L*u*v, XYZ, Yxy, Transmittance, Hunterlab, Munsell MI, CMYK |
Color difference formulas |
ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00 ΔEab(Hunter),555color classification |
Other colorimetric indices |
WI(ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby), YI(ASTM D1925,ASTM E313-00,ASTM E313-73), Tint(ASTM E313-00,CIE,Ganz),Metamerism index Milm, Stick color fastness, Color fastness, APHA, Pt-Co, Gardner |
Repeatability | light splitting reflectivity: standard deviation within 0.08% |
color values:ΔE*ab<=0.015(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals,Maximum:0.03) | |
Interface | USB |
Data storage | mass storage |
Light source longevity | 5 years, 1.5 million tests |
Size | 475*340*150mm(L*W*H) |
Weight | about 7kg |
Work temperature range | 0~45ºC, relative humidity 80% or below (at 35°C), no condensation |
Storage temperature range | 25ºC to 55ºC, relative humidity 80% or below (at 35°C), no condensation |
Standard accessories | AC power line, color management software, drive software, USB cable, black calibration tube, 40*10mm cuvette |
Self Drilling Screw,Countersunk Drilling Screw,Flat Head Window Screw
Head Screw,Hex Bolt,Blind Rivet Co., Ltd. , http://www.ejs-screw.com