High-pressure gear pump routine safety practices

High-pressure gear pump routine safety practices
First, the use of oil pump and jack required oil No. Working oil, generally No. 10 or No. 20 mechanical oil, hydraulic properties can also be similar to other similar oil, such as transformer oil. The oil poured into the tank must be filtered. Frequently used once a month filter, the tank should be cleaned regularly. The tank should generally maintain about 85% of the oil level, should be supplemented in time, the additional oil should be the same as the original pump oil. Oil temperature inside the tank should generally be 10 ~ 40 ℃ is appropriate, should not be used at negative temperature.
Second, the tubing under working pressure to avoid bending. The oil tank connected with oil pump and jack should be kept clean. When not in use, it should be blocked with screws to prevent silt from entering. The grease nipple exposed by oil pumps and jacks should be sealed with nuts to prevent dust and debris from entering the machine. After daily use, wipe the oil pump, remove oil grease on the copper wire cloth.
Third, the pump should not work under overload, safety valve pressure to be adjusted according to equipment rated pressure, non-arbitrarily adjusted.
Fourth, ground power, the chassis must be grounded, check the line insulation, before commissioning.
Fifth, high-pressure gear pump operation, the oil control valve should be loosen, and then start the pump until the normal operation of empty load, and then close the return valve, gradually screw into the valve stem, increase the load, and pay attention Gauge pointer is normal.
Sixth, the pump stops working, the valve should be slowly loosen the return valve, Park Taibang to be back to zero until the pressure gauge, before unloading the pipe jack nut. It is forbidden to change the tubing or pressure gauge during load.
Seven, with the dual-acting jack pump, dual-use oil pump to both oil is appropriate.
Eight, oil resistant rubber tube must be high pressure, the working pressure shall not exceed the rated pressure of high pressure gear pump or the maximum working pressure of the actual work. The tubing length should not be less than 2.5m. When an oil pump drives two jacks, the tubing specifications should be the same.