Mud pump common faults and troubleshooting

   Mud pump is a single-stage single-suction centrifugal pump used in mining, papermaking, printing and dyeing, environmental protection, graphite, mica, gold, ceramics, oil refining, petroleum, chemicals, farms, saltworks, Coking plant, construction, marble factory, gold mine, mud, quicksand, mud ponds, sewage ponds, dirty liquid to send thick slurry thick liquid, loading and suspended material sewage operations, but also for coal mine drainage and mud containing fluid. If combined with high-pressure water pump and water gun, it can be used as hydraulic mechanized earthwork unit, which can be used as digging and transporting of small water conservancy projects such as land leveling, dredging of river courses and ponds, and excavation, as well as urban air defense projects.

      Mud pump common fault and troubleshooting:

Slurry Pump Fault 1: The pump is not absorbing water

Reason: perfusion is not enough water, pump air can not be discharged, suction pipe leaks, front liner and impeller gap

Solution: continue perfusion water, check whether the pipeline leak, adjust the gap between the impeller and the front liner

Mud pump failure 2: pump on the water slow

Reason: the front liner and impeller gap, the water outlet pipe can not seal the air, emptying full

Solution: adjust the gap, adjust the outlet pipe, install the vacuum device

Mud pump failure 3: water pressure is small, small flow

Reason: pump air, the gap between the impeller and the front liner large clutch tight closed, impeller or liner wear

Solution: empty the pump gas, adjust the gap, adjust the clutch friction plate gap, replace the impeller or liner

Mud pump fault 4: pump vibration

The reason: the pump shaft and diesel engine (or motor) do not mind, impeller imbalance, bearing damage

Solution: adjust the concentricity, impeller balance test, replace the bearing

Mud pump failure 5: impeller shaft wear fast

The reason: high-pressure pump head low, dislocation, pump shaft and the back cover is not the heart

Solution: Replace the pump higher than the head of the mud pump, replace the packing, and adjust the concentricity

Mud pump failure 6: Pump worn fast

Reason: The construction environment (large particles) poor transmission distance, inlet pipe length

Solution: Change the battlefield, add afterburner, shorten the length of the inlet pipe to reduce cavitation