Compressed air station design method for correctly determining compressed air dew point

The effect of dew point on energy consumption and the method of correctly determining the dew point of compressed air are rarely noticed in the design of compressed air station; the technical performance and use effect of common non-thermal regenerative compressed air drying device and freeze drying device are analyzed; On this basis, the quantitative analysis and comparison of the energy consumption of the non-thermal regenerative compressed air drying device and the non-thermal regenerative composite drying device are emphasized. On the basis of comprehensive analysis and demonstration, the energy-saving design opinions that should be paid attention to when designing compressed air stations are put forward. Compressed air is directly related to the cost of power consumption and the cost of the product. Therefore, how to do well the energy-saving design of the enterprise compressed air station, so that it can meet the production requirements, but also save energy and reduce consumption has become an important part of the design of compressed air stations. This article discusses some aspects of the energy-saving design of compressed air stations.

Reasonable design of air compressor suction pipe position In the past, most of the compressed air stations using piston air compressors, air compressor suction pipe with suction filter, designed only before the suction filter A suction pipe (also equipped with an air suction muffler for environmental protection purposes). Since the 1990s, oil-injected screw air compressors have gradually become the mainstream in the market. However, most of the oil-injected screw-type air compressors have no suction pipes, so some compressed air stations using oil-injected screw air compressors use indoor suction. Indoor inhalation has the following disadvantages: high inspiratory temperature due to heat dissipation of the motor and air compressor, the indoor temperature of the compressed air station is about 35e higher than the outdoor temperature for a long time. Relevant experiments show that the exhaust volume of the compressor is increased every 3e of the inlet temperature. Will be reduced. The use of indoor suction will reduce the displacement of the compressor by 1% and 115%, resulting in wasted energy. In the heating area, the heating load will increase during the heating season. The air intake in the air compressor will be supplemented by the outdoor air. In the heating season, the amount of air to be replenished in the heating season must be heated by the heating facility to the indoor heating temperature. In the cold regions of the north, this heating The temperature difference between indoor and outdoor will be more than 30e. Take a 40Nm air compressor as an example. The working time of the annual heating season is 3000h, and the indoor and outdoor temperature difference is 20e. The annual waste of heat from the heating air compressor can be approximated as follows: In the formula Q) air compressor waste wasted heat, kJ; 1.293) compressed air density, kgPm at the same time, due to heating heating air compressor suction will reduce air compressor displacement by about 5% due to air density reduction, In this case, more energy is wasted than in the non-heating season.

Plastics Force Control System

Our plastics active contact flange, plastics Force Control System, plastics Constant Force Actuator have many advantages over other grinders. It can realize flexible grinding, quick repsond to surface changing, and instant adjusting. Traditional mechanic hand lacks flexibility, and it is not easy to adjust, hard to realize mass production.

Plastics Force Control System,Plastics active contact flange,Plastics constant force actuator

DARU Technology (Suzhou) Co., Ltd. , https://www.yiwufizz.com

Posted on