Features:
1.Adopts imported compressor such as Panosonic,Coopland,Tecumseh,thick copper pipe,special design of cooling system.
2.Fully made of 304# stainless steel,Environmentally friendly non-toxic frozen liquid.
3. High-strength design and thickening of the plate,make the machine particularly strong,even by severe impact or dumping will not affect its normal use.
4. Special motor to promote refrigerant heat exchange,Instead of traditional pump cooling at low temperatures and ordinary motor life is short.
5.Available to produce different flavors of ice,ice pops,ice bricks
6.The machine is equipped with a locked caster,easy to move,docked safety
7.With CE certificate.
How it works
1.Put the ice molds into brine pool. Make brine according with user manual.Â
2.Fill ice lolly material (jam, fruit juice, milk and so on) into ice molds, then insert theÂ
stick. Turn on the machine.Â
3.After 20-30 minutes when the ice lolly formed, bring out the ice mold to dissolving
 tank. Take out the stick in 3 minutes.Â
4.Put the ice lolly molds back into the machines. Fill lolly material in them and start
 the second batch.Â
5.You can also use packing machine to pack ice lollies into plastic bags.
Technical parameters
Model | Size (mm) | Weight (Kg) | Voltage (v) |
Power (KW) | Condense mode | Refrigerant | Capacity (pcs/day) |
1 mold | 770*570*1050+250 (motor height 250mm) |
110 | 220 | 1.6 | Air/water | R22/R404 | 3000 |
2 mold | 900*750*1050+250 (motor height 250mm) |
125 | 220 | 1.9 | Air/water | R22/R404 | 6000 |
4 mold | 1300*750*1050+250 (motor height 250mm) |
150 | 220/380 | 2.2 | Air/water | R22/R404 | 12000 |
6 mold | 2850x800x900 (motor height 250mm) |
220 | 220/380 | 2.6 | Air/water | R22/R404 | 16000 |
8 mold | 3250x800x1400 (motor height 250mm) |
280 | 380 | 5.5 | Air/water | R22/R404 | 26000 |
12 mold | 3200*1100*1050 (motor height 250mm) |
340 | 380 | 6.5 | Air/water | R22/R404 | 32000 |
18 mold | 4050x1100x1050 (motor height 250mm) |
450 | 380 | 9.2 | Air/water | R22/R404 | 36000 |
24 mold | 4270*1420*1050 (motor height 250mm) |
550 | 380 | 10 | Air/water | R22/R404 | 45000 |
32 mold | 4850x1400x1050 (motor height 250mm) |
650 | 380 | 13.5 | Air/water | R22/R404 | 72000 |
60 mold | 5750*2000*1050 (motor height 250mm) |
800 | 380 | 28.5 | Air/water | R22/R404 | 144000 |
120 mold | 10500*2000*1050 (motor height 250mm) |
1500 | 380 | 53.5 | Air/water | R22/R404 | 288000 |
Molds pictures
Produced ice lollies
Packed pictures
Except this ice lolly popsicle making machine,we also have related automaticice lolly packaging machine,ice popsicle display showcase,ice cream making machine,ice block making machine,ice cube maker,etc
,welcome to inquiry!
Gamma lab Nitrogen Generator is suitable for lab use, it makes use of pressure swing adsorption technology, separating and collecting nitrogen from air. It is easy to operate, plug and play, one simple push on starting button, nitrogen generator begin to work.
Laboratory Nitrogen Generator is one kind of Cabinet Nitrogen Generator. Its size is within 850 x 920 x 1100 mm, weight within 155 kg. Its details are as below:
2 Detailed technical specification
2.1 Compressed air consumption
The generator consumes a maximum of 115 slpm of compressed air to generate the required N2 flow. Air source is not included in this product.
2.2. Air supply pressure
Minimum air supply pressure shall be externally regulated to 600 kPa.
2.3. Air quality
This Generator is provided with one full set of FESTO filters, the air supplied to the Generator still need to be dry and oil-free.
2.4. N2 output
2.4.1. Quantity of N2 generate: the generator is capable of deliver 25 slpm nitrogen.
2.4.2. Delivery pressure: the generator delivers N2 at a pressure greater than 450 kPa.
2.4.3. O2 contamination level: O2 level in the N2 stream is not exceed 0.5%, and does not vary from peak to trough by more than 5% of the absolute concentration.
2.5 Dimensions
With package, the Generator size: 850 mm (Length)x 920 mm (width)x 1100 mm(height).
2.6 Weight
With package, the Generator weight is not more than 155 kg.
2.7 Wheels
The Generator is fitted with 2 fixed wheels at the rear and 2 swivel wheels with brakes at the front
2.8 Connection to power supply
The Generator has a panel mounted connector on the rear panel
• Current capacity at maximum temperature 2.5A<Imax<3.5A ( the power supply is capable of supplying 2.5A nominal)
• Jack plug, 5.5 x 2.5 x 9.5 mm, positive on the centre pin
• Maximum operating voltage at maximum temperature 30VDC.
• Minimum number of insertions/extractions while maintaining contact resistance specification AND without mechanical failure: > 5000
• Maximum contact resistance after specified minimum insertions: 30milliohms maximum
• Insulation resistance: min 100MegaOhms after environmental and durability tests
• Dielectric withstand Voltage : Min 500V for 60s
• Operating temperature range: -20 deg C to +70 deg C
2.9 Indicator
The Generator has a pushbutton illuminated switch on the front panel
• Button to be flush mounting or recessed into a bezel to avoid damage
• High corrosion resistance, either plastic or stainless steel body
• No symbol on button
• Size of button and bezel to be ~ 22mm to 30mm
• Mechanical Endurance : > 1000000 activations without mechanical failure
• Electrical Endurance : > 100000 cycles at maximum current and maintaining maximum specified contact resistance• Action mechanism : push on – push off
• Current handling capability : 4A DC min break, 4A DC min Make, inductive load (double the maximum expected current demand to give good lifetime)
• Maximum DC Working voltage : at least 40V DC
• Illumination type and color : LED, green
• Illumination Operating voltage: 24VDC
• Operating Temperature Range: -20deg C to +70 degC
• Terminal type : either screw terminal or 6.5mm spade type terminals
2.10. Solenoids
The solenoids on the gas control valves is 24 VDC.
2.11. Operation
2.11.1. Operating cycle
A typical operating cycle for the Generator is 1 start per day and then run for 8 hours per day, which is equivalent to 2000 hours of operation per year. Depending upon the particular site, operating time could be anywhere between 0 and 24 hours per day.
2.11.2. Operation at shutdown
When the power is turned off, the pressure vessels is maintained in the pressurized state by closing the two exhaust valves.
2.12. Start up
2.12.1. Start up time
Start up times means the time from start up to producing qualified nitrogen.
The time to complete start up is less than 15 minutes.
2.13. Gas connections
The two external gas connections on the Generator, Air In and N2 Out, are constructed from brass and are to suit ¼" (6.35 mm) OD tubing. There are labeling in English next to these connections, [Air In" and [N2 Out", as part of the rating label.
2.14. Environmental requirements
2.14.1. Operating temperatures
The Generator is normally operated within performance specification over the temperature range:
10ºC - 35ºC from 0 – 3000 m, and 10ºC - 25ºC from 3000 – 4500 m
The Generator can operate safely over the temperature range:
5ºC - 35ºC from 0 – 3000 m, and 5ºC - 25ºC from 3000 – 4500 m
2.14.2. Noise level requirements
Noise level from the Generator is less than 72dBa at 1m distance. This is achieved by fitting silencers on the exhaust vents.
2.15. Life Requirements
The Generator can operate with a mean time between failure of 5 years minimum.
Lab Use Nitrogen Generator,Laboratory Nitrogen Generator,Laboratory Nitrogen Gas Generator,Laboratory Use High Purity Nitrogen Generator
Shandong Gamma Gas Engineering Co. Ltd. , http://www.gammagas.com