-Accuracy class: OIML(111)
-Weighing scope: 10-150(t)
-Truck scale length: 5-24m
-Truck scale width: 3-3.4m
-Working environment:
-Indicator surrounding: Temperature: -10+40 degree
-weighting table: -30+65 degree
-Relative humidity: Below 95%
-Power supply: 220V(AC) 50Hz
-Weighing capacity: 10Ton-150Ton
Standard accessory part include:
1. 1PCS digital weighing indicator.
2. 6-12PCS high accuracy digital load cell
3. 1PCS Panasonic printer
4. 1PCS waterproof junction boxes.
5. 1PCS keda dedicated shielded cable.
6. 1 whole set Bolts-screws, limit screw, loading cell screw, cover plate screw, installation tools.
-SCS Truck scale platform size (m):
Model | Platform Size(width*length)(m) | Capacity(T) | Division(kg) |
SCS-KD-10 | Â 3x7 | 10 | 5 |
SCS-KD-20 | Â 3x7Â | 20 | 10 |
SCS-KD-30 | Â 3x7 3x10 | 30 | 10 |
SCS-KD-40 | Â 3x7 3x10 3x12 3x14Â | 40 | 10 |
SCS-KD-50 | Â 3x10 3x12 3x14 3x16 | 50 | 10 |
SCS-KD-60 | Â 3x10 3x12 3x14 3x16 | 60 | 10 |
SCS-KD-80 | Â 3x12 3x14 3x16 3x18 3x21 | 80 | 10 |
SCS-KD-80 3x14 3x16 3x18 3x21 | 100 | 20 | Â |
SCS-KD-150 3x18 3x21 3x24 | 150 | 20 | Â |
PS: We can design and manufacture by customers requirement. |
-Accuracy class: OIML(111)
-Weighing scope: 10-150(t)
-Truck scale length: 5-24m
-Truck scale width: 3-3.4m
-Working environment:
-Indicator surrounding: Temperature: -10+40 degree
-weighting table: -30+65 degree
-Relative humidity: Below 95%
-Power supply: 220V(AC) 50Hz
-Weighing capacity: 10Ton-150Ton
Standard accessory part include:
1. 1PCS digital weighing indicator.
2. 6-12PCS high accuracy digital load cell
3. 1PCS Panasonic printer
4. 1PCS waterproof junction boxes.
5. 1PCS keda dedicated shielded cable.
6. 1 whole set Bolts-screws, limit screw, loading cell screw, cover plate screw, installation tools.
-SCS Truck scale platform size (m):
Model | Platform Size(width*length)(m) | Capacity(T) | Division(kg) |
SCS-KD-10 | Â 3x7 | 10 | 5 |
SCS-KD-20 | Â 3x7Â | 20 | 10 |
SCS-KD-30 | Â 3x7 3x10 | 30 | 10 |
SCS-KD-40 | Â 3x7 3x10 3x12 3x14Â | 40 | 10 |
SCS-KD-50 | Â 3x10 3x12 3x14 3x16 | 50 | 10 |
SCS-KD-60 | Â 3x10 3x12 3x14 3x16 | 60 | 10 |
SCS-KD-80 | Â 3x12 3x14 3x16 3x18 3x21 | 80 | 10 |
SCS-KD-80 3x14 3x16 3x18 3x21 | 100 | 20 | Â |
SCS-KD-150 3x18 3x21 3x24 | 150 | 20 | Â |
PS: We can design and manufacture by customers requirement. |
The boiler water wall is the main radiation heat surface, arranged inside the boiler chamber and proceeds the heat exchange directly with the high temperature flame. The convection tubes are the convection heat surface of the boiler, arranged between the boiler chamber outlet and the end heat surface and proceed the heat exchange directly with the high temperature fume. The water wall and convection tubes are the main heat surface of the boiler, the tubes diameter for both generally usedΦ 51-60mm boiler steel tubes, also as the request.
The first type is the bare pipe water wall. This is the simplest structure of the water wall. The advantage is that ordinary seamless steel pipes can be used, and it is more convenient to replace the water wall pipe. The disadvantage is that the temperature of the furnace wall is still high, and heavy refractory bricks are required. The steel frame of the corresponding boiler should be strengthened. , The air leakage of the furnace wall is relatively large. Old-fashioned high-pressure boilers and medium and small boilers are used more frequently.
The second tupe is the membrane water wall. The membrane water wall is welded by seamless steel tubes with fins. The Water Wall Tubes are connected by fins to make the water wall into a whole. This kind of water wall is called a membrane water wall. Its function is to strengthen the heat transfer of the water wall and greatly reduce the temperature of the furnace wall. The furnace wall does not need refractory bricks, but only requires thermal insulation materials. Compared with the conventional heavy furnace wall, the weight can be reduced by 60% ~ 70%, the furnace wall heat storage is reduced by 80%, the start and stop time is shortened, and the fuel consumption is reduced. The load of the furnace steel frame is greatly reduced, saving refractory materials and steel.
The third type is the pierced pipe water wall. The barbed pipe water wall pipe is made by welding many grab nails with a length of 20 to 26 mm and a diameter of 6 to 12 mm on the water wall pipe. It is mainly used to lay the gas belt. Generally, for boilers that burn fuel with low calorific value and low volatile content, in order to stabilize the fire, pierced pipe water walls are often used for laying the fire protection belt.
Wall Mounted Boiler,Water Wall Tubes,Wall Mounted Combi Boiler,Water Wall Tubes In Boiler
Jinan Yuanda Power Equipment Co.,Ltd. , https://www.ydpowerequipment.com