S&A air cooled chiller for 120W diode laser

A customer intended to purchase air cooled chiller to cool 120W diode laser, the technical requirement as below:

1. Required cooling capacity in 0.8 kW at 20 °C target water temperature
and 40 °C ambient temperature
2. Adjustable working temperature from 5 °C to 40 °C
3. Operating ambient temperature from 5 °C to 40 °C
4. Glycol mixing ratio in 15%
5. Require 16 l/min flow rate @ 2.5 bar operating pressure
To satisfy both the cooling capacity and water pressure, we recommend S&A chiller CW-6000 with 3KW cooling capacity and ±0.5℃ temperature accuracy.
CW-6000 technical parameter: http://Products/ChillerCW60003000Wco.html
chiller

CONTACT S&A

TE:+86-20-89301885

FAX:+86-20-84309967

SKYPE: teyuchiller

Email:

Website: http://

Counter Current Closed Cooling Tower

A cooling tower is a device that uses water as a circulating coolant to absorb heat from a system and release it to the atmosphere to lower the water temperature.

Closed Cooling Tower has two operation modes.

Air cooling, air cooling + spraying.

The electronic control system actively stops the two switching modes according to the requirements of working conditions to save energy and reduce consumption.

Counter Current Closed Cooling Tower,Counter Current Cooling Tower,Countercurrent Cooling Tower, Cooling Tower For Sale

Wuxi Ark Fluid Science Technology Co., Ltd. , https://www.arkfluid.com

Posted on