Mold incubator maintenance method
The teaching equipment belonging to the mold incubator is widely used in medical and health, biopharmaceutical, agricultural scientific research, and environmental protection. It is an indispensable special equipment for the cultivation and preservation of microorganisms, plant cultivation, and experimental biological culture for breeding. Mold incubator maintenance is essential during daily use. The correct maintenance method can effectively reduce the occurrence of failure.
1. Adjust the height with the adjusting screw at the bottom of the mold incubator so that the cabinet can be placed smoothly.
2. Plug in the power outlet (the power supply should be well grounded), press the power switch, and the display will light up. At this time, the display shows the actual temperature and humidity inside the incubator.
3. Installation of humidifier: Plug the power plug of the humidifier into the power socket on the back of the instrument, and then connect the humidifier tube of the instrument with the humidifier, and the connection must be tightly connected. The water in the humidifier tank must be properly operated according to the instructions.
4, temperature adjustment: Press the temperature setting button, the digital display is the set value, rotate the temperature to adjust the potentiometer to the desired temperature value, release the button, the digital display is the actual temperature in the training room. At this time, if the actual temperature in the incubator is smaller than the set temperature, the heating indicator light is on and the heater starts heating; if the actual temperature in the incubator is higher than the set temperature, the refrigeration indicator is on, and the refrigeration system begins to cool; for example, the heating indicator lamp If the indicator light is dark, the incubator is at a constant temperature.
5. Humidity adjustment: Press the humidity setting button, the digital display is the setting value, rotate the humidity to adjust the potentiometer to the required humidity value, release the button, the digital display is the actual humidity in the mold incubator. When the actual humidity in the cultivating room is smaller than the set humidity, humidification humidifies the humidifying lamp in the culturing chamber; when the actual humidity in the culturing room is greater than the set humidity, the humidifier stops working at this time, and the humidifying indicator lights Off.
6. If the inside of the box does not need to be sterilized, the sterilizing switch on the panel should be placed in the “off” position. ?
7, when the temperature is set, can not easily turn the temperature control knob back and forth several times, so as not to start the compressor frequently, causing the compressor to appear overload, affect the life of the compressor.
8, the back of the machine is equipped with two sets of fuse boxes, 2A? is a cooling and heating load fuse box, and 8A? is a control power supply fuse box. If the machine operation fails, for example, the temperature control fails, no heating or cooling, the power must be cut off. Check whether the fuse is intact and check the corresponding parts.
9. Care must be taken when handling. The angle between the plane and the horizontal plane must not be less than 45°.
10, when the use of low temperature, should be periodically drained in the tank at the bottom of the stagnant water in the water.
11. If there is any problem with the humidifier, please repair it according to the warranty on the humidifier manual.
12. When the humidity sensor is in a high humidity state for a long time, condensation will form, that is, the humidity display value will remain high. If an accurate humidity display value is required, the incubator box door should be opened to allow the humidity sensor to be at room temperature. In the natural drying, you can continue to use.
13, in order to maintain the appearance of the equipment, are not allowed to use the acid or alkali and other corrosive objects to wipe the surface, the box can be dry with a dry cloth regularly.

Big Capacity Dosing Pump

*High performance with the capacity up to 1200L/H

*The outstanding valves for pressure application up to 12Bar

*This series pump is designed for durability and cost effectiveness

*Durable diaphragm: mechanical actuated diaphragm, leakage free 

*Easily installation, simple operation and convenience maintenance, ready to use for customer                                                                                                                                    

*High measurement precision, capacity can be adjusted from 0 to 100 percent during operation                                                                                                                                   

*Strong anti-corrosiveness, used for quite range of chemical                                              

*Economical and practical                                                                                                                                            

* Rugged construction designed which allowed pump to provide safe services  at severe operation condition          

*Maximum temperature of pump liquid: 10℃ to 40℃

*The pump can be used to deliver the solution which is high-viscosity, corrosive and dangerous                          