Lab Equipment of Inductive Coupling Plasma Mass Spectrometer

  • Model NO.: ICP-MS2000
  • Warranty: 1 Year
  • Advantage: High Resolution
  • Wavelengths: Mass Spectrometer
  • Light Number: Monochromator
  • Customized: Customized
  • Transport Package: International Import and Export Carton
  • Origin: Jiangsu Suzhou
  • Application: Laboratory Instruments
  • Detection Method: Mass Spectrometer
  • Principle: New Spectrometer
  • Dispersive Element: Mass Detector
  • Certification: RoHS, ISO9001, CE
  • Trademark: skyray instrument
  • Specification: CE, ISO
  • HS Code: 90273000
 ICP-MS 2000 is the first industrialized inductively coupled plasma mass spectrometer in China with its performance reaching China national standard.

Configurations:

Inlet:Open modular sample introduction system with externally mounted atomizer is able to locate automatically
Torch Alignment:X,Y and Z axes are accurately PC-controlled,with all the adjusted parameters saved in analysis methods
Advanced plasma shielding:greatly improving sensitivity and limits of detection of light elements(ppm level)
Valve gate:PC-controlled valve to retain vacuum,facilitate assembly,disassembly and cleaning of the sampling and skimmer cones when vacuum system is on
Ion lens: Hexapole ion guide can transmit ions in full mass range efficiently with automatic ion focusing and tuning
Detector:ETP dual-mode detector,discrete dynode electron multiplier
Vacuum chamber: wireless connection
Power-off protection:automatically shut down to protect the system in case of unexpected power failure
Software:automatic control of instrument and accessories,( Windows 2000/XP/vista/window7,both 32 and 64 bit are ok), professional system
 
Specifications
Mass Range:2~255 amu
Dynamic (Linear) Range:≥108 
Sensitivity(cps/mg/L): Be≥5×106 ; In≥60×106 ; U≥60×106
Limit of Detection(ng/L): Be≤5;In ≤0.5;U≤0.5 
Resolution (amu):0.6~0.8 amu
SNR (Signal to Noise Ratio):≥50×106 
Background: ≤2 cps(full mass range)
Variance:≤0.05 amu/24 h
Stability( RSD): short term≤2 %;long term≤3 %
Oxides:CeO+/Ce+≤3%
Double charged:69Ba2+/138Ba+ ≤3% 
Isotope Ratio Precision:(107Ag/109Ag)≤0.2%
Abundance Sensitivity:≤1×10-6low mass;≤5×10-7high mass
ICP-MS2000 inside construction 


ICP-MS burning chamber


ICP-MS2000 software

 

Thin Wall Mold

cheap plastic injection molds and mould manufacturer 1-Start from part design analysis 2-Mold design drawing and DFM report available so you can see how is the mold going to be before mold making 3-If product is complex,moldflow report will be present as well 4-In house mold making shop ensure you mold quality under well control. 5-Normally it takes 20-40 days to make mold,precise time depends on part design

Thin Wall Mold,Thin Wall Container Mould,Thin Wall Mould,Ultra Thin Wall Injection Molding

Taizhou Zijing Plastic and Mould Co.,Ltd. , https://www.zijingmould.com

Posted on